CardioMEMS HF System for Pulmonary Pressure Monitoring in Heart Failure Patients Appr - منتديات الرياضة

ryan

العودة   ryan > منتدى تغذيات > منتديات الرياضة

إضافة رد
 
أدوات الموضوع انواع عرض الموضوع
  #1  
قديم 05-30-2014, 12:01 AM
rss rss غير متواجد حالياً
Senior Member
 
تاريخ التسجيل: Sep 2012
المشاركات: 721,669
افتراضي CardioMEMS HF System for Pulmonary Pressure Monitoring in Heart Failure Patients Appr

CardioMEMS HF System for Pulmonary Pressure Monitoring in Heart Failure Patients Approved by FDA (VIDEO)
CardioMEMS System Pulmonary Pressure Monitoring
Heart disease that progresses into Heart Failure leaves people in a dangerous state in which acute decompensation events can happen any time. Being able to monitor such Patients day and night **rmally requires hospitalization, but a new implant System just approved by the FDA can offer capabilities similar to right Heart catheterization while the patient is back home.

CardioMEMS System Pulmonary Pressure MonitoringThe CardioMEMS HF System from*CardioMEMS (Atlanta, GA)*consists of an implantable, battery-free sensor that is implanted into the distal Pulmonary artery to continuously measure the Heart rate along with systolic, diastolic, and mean pressures. The implant is delivered using a matching vascular catheter and readings from the implant are gathered by a bedside electronics unit that also wirelessly powers the implant. The data is transmitted to an online portal where the patient’s cardiologist can check the readings collected by the CardioMEMS HF.

Some details about the tech**logy inside the implant, according to the product page:
The sensor is a resonant circuit consisting of a capacitor and an inductor. The capacitance of the sensor is a function of the Pressure in the sensor’s environment and the resonant frequency of the sensor is a function of the capacitance and is measured by the electronics unit. Because of the presence of the inductor coil, the sensor can be electromagnetically coupled and the resonant frequency of the LC (inductor-capacitor) circuit can be measured remotely. This allows for wireless communication with the sensor and eliminates the need for a battery.



Product page: CardioMEMS HF System…

Press release: FDA approves first implantable wireless device with remote monitoring to measure pulmonary artery pressure in certain heart failure patients…

CardioMEMS System Pulmonary Pressure Monitoring CardioMEMS System Pulmonary Pressure Monitoring CardioMEMS System Pulmonary Pressure Monitoring
CardioMEMS System Pulmonary Pressure Monitoring

كلمات البحث

العاب ، برامج ، سيارات ، هاكات ، استايلات


رد مع اقتباس
إضافة رد


تعليمات المشاركة
لا تستطيع إضافة مواضيع جديدة
لا تستطيع الرد على المواضيع
لا تستطيع إرفاق ملفات
لا تستطيع تعديل مشاركاتك

BB code is متاحة
كود [IMG] متاحة
كود HTML معطلة

الانتقال السريع


الساعة الآن 04:16 PM


Powered by vBulletin® Copyright ©2000 - 2026, Jelsoft Enterprises Ltd. TranZ By Almuhajir
This Forum used Arshfny Mod by islam servant